CONTROLLER of SOLAR WATER HEATER, 220V, 3 temperature sensors, for - TopicsExpress



          

CONTROLLER of SOLAR WATER HEATER, 220V, 3 temperature sensors, for hot water Link:ebay.au/itm/CONTROLLER-SOLAR-WATER-HEATER-220V-3-temperature-sensors-hot-water-/330941492587?pt=AU_HotWaterSystems&hash=item4d0da66d6b Application: It is used for seperated pressurized solar water heating system. Voltage: 220v Introduction: 1 collector array – 1 storage tank – 1 pump and auxiliary heating Description: The solar circuit pump (R1) is switched on as soon as the switch-on temperature difference (△Ton) between the collector array (T1) and the storage tank (T2) is reached. If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (△Toff), or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump ( R1) is switched off. Back-up heating by auxiliary boiler (detailed see paragraph 4.3): Within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased. Main technical data Appearance of controller 120mm×120mm×18mm Power consumption < 3W Accuracy of temperature ±2℃ measuring Range of collector -10~220℃ temperature measuring Range of tank 0~110℃ Suitable power of pump three pumps, ≤ 600W Suitable power of power ≤ 1500W Electrical heater Inputs Temperature sensor: 1 x Pt1000 sensor (≤500℃) for collector (silicon cable≤280℃), 2 x NTC10K, B3950 sensor (≤ 135℃) for tank, (PVC cable ≤105℃), Outputs 3 relays, for circulation pumps or 3way electromagnetic valve 1 relay for electrical heater Ambient temperature -10~50 ℃ Water proof grade IP40 Main functions 1.Main menu DT O & DT F Temperature difference function 2.Main menu-THET timing heating 3.TEMP Temperature main menu 4.EM Emergency collector temperature (emergency switch-off temperature of collector) 5.CMX Maximum limited collector temperature (collector cooling function) 6.CMN low temperature protection of collector 7.CFR frost protection of collector 8.SMX Maximum temperature of tank 9.REC Tank re-cooling function 10.Celsius and Fahrenheit temperature transferring 11.FUN Auxiliary function 12.DVWG Anti-Legionella function 13.CIRC Temperature controlled hot water circulation pump 14.nMIN Solar circulation pump speed adjusting (RPM speed controlling)(not available in this model) 15.OHQM Thermal energy measuring (not available in this model) 16.INTV Pump interval function (not available in this model) 17.BYPR High temperature by-pass function (tank temperature automatically adjusting) 18. HND Manual mode 19.PASS Password setting 20.LOAD Recovery to factory setting 21.ON/OFF button 22.Holiday function 23.Manual heating 24.Temperature query function 25.Memory Protection 26.Anti-dry heating Protection 27.Screen protection
Posted on: Tue, 27 Aug 2013 05:53:53 +0000

Trending Topics



Recently Viewed Topics




© 2015