Dispositivos supraglóticos versus intubación traqueal para - TopicsExpress



          

Dispositivos supraglóticos versus intubación traqueal para manejar la vía aérea durante anestesia en obesos Supraglottic airway devices versus tracheal intubation for airway management during general anaesthesia in obese patients. Nicholson A1, Cook TM, Smith AF, Lewis SR, Reed SS. Cochrane Database Syst Rev. 2013 Sep 9;9:CD010105. doi: 10.1002/14651858.CD010105.pub2. Abstract BACKGROUND: The number of obese patients requiring general anaesthesia is likely to increase in coming years, and obese patients pose considerable challenges to the anaesthetic team. Tracheal intubation may be more difficult and risk of aspiration of gastric contents into the lungs is increased in obese patients. Supraglottic airway devices (SADs) offer an alternative airway to traditional tracheal intubation with potential benefits, including ease of fit and less airway disturbance. Although SADs are now widely used, clinical concerns remain that their use for airway management in obese patients may increase the risk of serious complications. OBJECTIVES: We wished to examine whether supraglottic airway devices can be used as a safe and effective alternative to tracheal intubation in securing the airway during general anaesthesia in obese patients (with a body mass index (BMI) > 30 kg/m(2)). SEARCH METHODS:We searched for eligible trials in the following databases: Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 8, 2012), MEDLINE via Ovid (from 1985 to 9 September 2012) and EMBASE via Ovid (from 1985 to 9 September 2012). The Cochrane highly sensitive filter for randomized controlled trials was applied in MEDLINE and EMBASE. We also searched trial registers such as clinicaltrials.gov and the Current Controlled Clinical Trials Website (controlled-trials/) for ongoing trials. The start date of these searches was limited to 1985, shortly before the first SAD was introduced, in 1988. We undertook forward and backward citation tracing for key review articles and eligible articles identified through the electronic resources. SELECTION CRITERIA: We considered all randomized controlled trials of participants aged 16 years and older with a BMI > 30 kg/m(2) undergoing general anaesthesia. We compared the use of any model of SAD with the use of tracheal tubes (TTs) of any design. DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by The Cochrane Collaboration. Two review authors independently assessed trial quality and extracted data, including information on adverse events. We contacted study authors for additional information. If sufficient data were available, results were presented as pooled risk ratios (RRs) with 95% confidence intervals (CIs) based on random-effects models (inverse variance method). We employed the Chi(2) test and calculated the I(2) statistic to investigate study heterogeneity. MAIN RESULTS: We identified two eligible studies, both comparing the use of one model of SAD, the ProSeal laryngeal mask airway (PLMA) with a TT, with a total study population of 232. One study population underwent laparoscopic surgery. The included studies were generally of high quality, but there was an unavoidable high risk of bias in the main airway variables, such as change of device or laryngospasm, as the intubator could not be blinded. Many outcomes included data from one study only.A total of 5/118 (4.2%) participants randomly assigned to PLMA across both studies were changed to TT insertion because of failed or unsatisfactory placement of the device. Postoperative episodes of hypoxaemia (oxygen saturation < 92% whilst breathing air) were less common in the PLMA groups (RR 0.27, 95% CI 0.10 to 0.72). We found a significant postoperative difference in mean oxygen saturation, with saturation 2.54% higher in the PLMA group (95% CI 1.09% to 4.00%). This analysis showed high levels of heterogeneity between results (I(2) = 71%). The leak fraction was significantly higher in the PLMA group, with the largest difference seen during abdominal insufflation-a 6.4% increase in the PLMA group (95% CI 3.07% to 9.73%).No cases of pulmonary aspiration of gastric contents, mortality or serious respiratory complications were reported in either study. We are therefore unable to present effect estimates for these outcomes.In all, 2/118 participants with a PLMA suffered laryngospam or bronchospasm compared with 4/114 participants with a TT. The pooled estimate shows a non-significant reduction in laryngospasm in the PLMA group (RR 0.48, 95% CI 0.09 to 2.59).Postoperative coughing was less common in the PLMA group (RR 0.10, 95% CI 0.03 to 0.31), and there was no significant difference in the risk of sore throat or dysphonia (RR 0.25, 95% CI 0.03 to 2.13). On average, PLMA placement took 5.9 seconds longer than TT placement (95% CI 3 seconds to 8.8 seconds). There was no significant difference in the proportion of successful first placements of a device, with 33/35 (94.2%) first-time successes in the PLMA group and 32/35 (91.4%) in the TT group. AUTHORS CONCLUSIONS: We have inadequate information to draw conclusions about safety, and we can only comment on one design of SAD (the PLMA) in obese patients. We conclude that during routine and laparoscopic surgery, PLMAs may take a few seconds longer to insert, but this is unlikely to be a matter of clinical importance. A failure rate of 3% to 5% can be anticipated in obese patients. However, once fitted, PLMAs provide at least as good oxygenation, with the caveat that the leak fraction may increase, although in the included studies, this did not affect ventilation. We found significant improvement in oxygenation during and after surgery, indicating better pulmonary performance of the PLMA, and reduced postoperative coughing, suggesting better recovery for patients. onlinelibrary.wiley/doi/10.1002/14651858.CD010105.pub2/pdf
Posted on: Sun, 07 Dec 2014 12:04:39 +0000

Trending Topics



tyle="min-height:30px;">
Oscar De La Hoya named Promoter of the Year by Sports
~1979 Worship was indeed important to the early settlers of Fort
. Ela: Alô? Ele: Alô, sou eu! Ela: (Ela fica em silêncio um
To be wrong is not just the same as to do wrong. The person who is
Inexpensive Hoya - 67mm Close-up lens kit x 3 BUY NOW! Save on
1998 Toyota 4RUNNER 4 RUNNER Service Shop Repair Manual Set
Our father whos art in heaven.....will u place my art in ur

Recently Viewed Topics




© 2015