HUD Guidelines Regarding Winterizations This section - TopicsExpress



          

HUD Guidelines Regarding Winterizations This section provides instruction for maintenance of utilities and winterization of properties to protect against freeze damage. It also addresses maintenance of wells and properties with sump pumps. Utilities Unless identified in the variations section of this attachment, utilities are to be turned off. In states where heat is to remain on, the temperature should be maintained at 55 degrees Fahrenheit unless otherwise noted in the local variations. Condominiums and Attached Dwellings At condominiums and attached dwellings in Planned Unit Developments (PUDs), water services and utilities should remain on if the systems are shared with other units. M&M Contractors should be contacted for directions on maintaining water services at properties where a community water service is involved and for electrical services at condominiums or townhouses, duplexes, attached dwellings in PUDs, where such services should be left on due to homeowners’ association or party wall requirements. Equipment Damage When there is a jurisdictional requirement for heat to remain on and a repair or replacement is needed to make the heating system operational, the Mortgagee should contact the M&M Contractor for instructions when the repair or replacement exceeds $250.00. The Mortgagee is responsible for damages to plumbing and heating systems caused by untimely and/or improper maintenance. Sump Pumps Where there is an existing sump pump used to keep basements or crawl space dry, the Mortgagee should leave the electricity on to assure the property is undamaged by flooding, regardless of whether the property is located in a state where utilities are required to be off. The Mortgagee should check to make sure the sump pump is operating. Mortgagees should request prior written approval from the M&M contractor if the cost of installing a sump pump exceeds $250. Utility Accounts Utility accounts including electricity, gas, home heating oil and water, should be in the Mortgagee’s name until conveyance of the property to HUD. The Mortgagee should pay the bill and may claim reimbursement for utility costs covering the period from the date of vacancy until the end of the billing cycle that includes the date of conveyance. Payment of a utility bill that includes charges for a portion of a billing cycle that is post conveyance is the exception to HUD’s policy on non-reimbursement of expenses after the conveyance date. It is the Mortgagee’s responsibility to notify the utility company that ownership of the security property has been transferred to HUD (to the attention of the M&M contractor), upon conveyance. A copy of the notice should be maintained in the claim review file. In states where utilities should remain on, if there is any reason to believe that a Mortgagor may abandon a property, the Mortgagee should contact the utility company to request that the Mortgagee be notified of non-payment of utilities so that utilities can be transferred to the Mortgagee’s name and the heat remain on if the Mortgagor vacates. Propane and Oil Systems If the property has a propane or oil heating system, put a “KEEP FULL” contract on with a local supplier; in those jurisdictions, where the heat should remain “ON.” Domestic Water Supply Systems If the water supply source is a public system, the utility should be contacted to turn off the water supply at the curb, unless otherwise indicated in the local variations. The Mortgagee should not cut water lines or remove water meters. (A non-reimbursable charge may be imposed by the water utility for unauthorized water meter removal). The water department or provider should be notified when water is turned off so that a final meter reading can be done. The Mortgagee should ensure that this is completed. Where a water heater has to be installed, the Department will reimburse up to $350 for an electric water heater or up to $420 for a gas water heater, which includes the cost of installation. Regarding Properties With Well Water If the water supply is a private well, the Mortgagee should turn off the well at the breaker panel and tape off the breaker, disconnect the water supply line between the property and pressure tank and install a hose bib on the pressure tank side of the breaker. The hose bib should then be tagged “For Water Testing”. All pressure tanks should be drained. If pump is surface mounted, drain pump housing, - if submersible, then disconnect the check valve and drain all pump, suction, and discharge pipes. All fixtures should be winterized. Reduced Pressure Zone Device (RPZ or RPZD) A reduced pressure zone device (RPZ) is a type of backflow prevention device used to protect domestic water supplies from contamination. Mortgagees should contact the local health departments and/or state and local agencies with regard to any jurisdictional requirements for the installation and/or use of the RPZ device on all wet heat systems. Mortgagees should obtain two independent competitive bids. Winterization In jurisdictions where winterization is required, properties are to be winterized between October 1st and March 31st. Properties should only be winterized once. However, a property should be re-winterized if the initial winterization is violated (no longer effective) and the Mortgagee obtains prior approval from the M&M Contractor. Unless otherwise specified by local variation, the winterization process must include cleaning toilets and draining of all plumbing and heating systems in a manner sufficient to prevent freeze and/or other damage. Use of air pressure to clear the system, or in some cases, adding antifreeze to the system is both acceptable, provided that the effect prevents freeze-ups. All winterization should be performed in accordance with state and local codes, ordinances and regulations. Before and after photographs are required along with any other supporting documentation to support a claim for re-imbursement. Dry Heat Systems The hot water heater and all domestic water supply and distribution piping must be drained in a manner sufficient to prevent freeze and/or other damage. All faucets and valves should REMAIN OPEN during the process, and then closed after draining is completed. Adequate amounts of antifreeze are to be placed in all fixture traps, including toilet tanks and bowls. Wet Heat, Radiant, Hydronic or Hot Water Baseboard Systems The winterization requirements outlined above apply. In addition, the house boiler system must be drained in a manner sufficient to prevent freeze and/or other damage. All radiator vents are to be opened in the process. Bleeder pins should not be removed from the radiators. Any radiant heat piping should be drained and blown dry with the use of an air compressor and an adequate amount of antifreeze is to be put in the radiant piping. Steam Heat Systems A steam heat system will have radiators with valves at the bottom of the radiator; a careful determination as to whether the system is hot water or steam is important to ensure proper action is taken. The Mortgagee should determine if the system is operable and if there are any leaks. If any problems with the steam heat system exist, this information should be reported to the M&M Contractor. Additionally, the Mortgagee must drain the property’s boiler system in a manner sufficient to prevent freeze and/or other damage. All radiator vents are to be opened in the process and bleeder pins should not be removed from the radiators, before shutting down the heating system. Pressurize the system with an air compressor to 35 pounds and inspect for leakage. The expectation for a properly prepared system is that it will hold air pressure with no leakage for a minimum of one-half hour HUD Guidelines Regarding Winterizations This section provides instruction for maintenance of utilities and winterization of properties to protect against freeze damage. It also addresses maintenance of wells and properties with sump pumps. Utilities Unless identified in the variations section of this attachment, utilities are to be turned off. In states where heat is to remain on, the temperature should be maintained at 55 degrees Fahrenheit unless otherwise noted in the local variations. Condominiums and Attached Dwellings At condominiums and attached dwellings in Planned Unit Developments (PUDs), water services and utilities should remain on if the systems are shared with other units. M&M Contractors should be contacted for directions on maintaining water services at properties where a community water service is involved and for electrical services at condominiums or townhouses, duplexes, attached dwellings in PUDs, where such services should be left on due to homeowners’ association or party wall requirements. Equipment Damage When there is a jurisdictional requirement for heat to remain on and a repair or replacement is needed to make the heating system operational, the Mortgagee should contact the M&M Contractor for instructions when the repair or replacement exceeds $250.00. The Mortgagee is responsible for damages to plumbing and heating systems caused by untimely and/or improper maintenance. Sump Pumps Where there is an existing sump pump used to keep basements or crawl space dry, the Mortgagee should leave the electricity on to assure the property is undamaged by flooding, regardless of whether the property is located in a state where utilities are required to be off. The Mortgagee should check to make sure the sump pump is operating. Mortgagees should request prior written approval from the M&M contractor if the cost of installing a sump pump exceeds $250. Utility Accounts Utility accounts including electricity, gas, home heating oil and water, should be in the Mortgagee’s name until conveyance of the property to HUD. The Mortgagee should pay the bill and may claim reimbursement for utility costs covering the period from the date of vacancy until the end of the billing cycle that includes the date of conveyance. Payment of a utility bill that includes charges for a portion of a billing cycle that is post conveyance is the exception to HUD’s policy on non-reimbursement of expenses after the conveyance date. It is the Mortgagee’s responsibility to notify the utility company that ownership of the security property has been transferred to HUD (to the attention of the M&M contractor), upon conveyance. A copy of the notice should be maintained in the claim review file. In states where utilities should remain on, if there is any reason to believe that a Mortgagor may abandon a property, the Mortgagee should contact the utility company to request that the Mortgagee be notified of non-payment of utilities so that utilities can be transferred to the Mortgagee’s name and the heat remain on if the Mortgagor vacates. Propane and Oil Systems If the property has a propane or oil heating system, put a “KEEP FULL” contract on with a local supplier; in those jurisdictions, where the heat should remain “ON.” Domestic Water Supply Systems If the water supply source is a public system, the utility should be contacted to turn off the water supply at the curb, unless otherwise indicated in the local variations. The Mortgagee should not cut water lines or remove water meters. (A non-reimbursable charge may be imposed by the water utility for unauthorized water meter removal). The water department or provider should be notified when water is turned off so that a final meter reading can be done. The Mortgagee should ensure that this is completed. Where a water heater has to be installed, the Department will reimburse up to $350 for an electric water heater or up to $420 for a gas water heater, which includes the cost of installation. Regarding Properties With Well Water If the water supply is a private well, the Mortgagee should turn off the well at the breaker panel and tape off the breaker, disconnect the water supply line between the property and pressure tank and install a hose bib on the pressure tank side of the breaker. The hose bib should then be tagged “For Water Testing”. All pressure tanks should be drained. If pump is surface mounted, drain pump housing, - if submersible, then disconnect the check valve and drain all pump, suction, and discharge pipes. All fixtures should be winterized. Reduced Pressure Zone Device (RPZ or RPZD) A reduced pressure zone device (RPZ) is a type of backflow prevention device used to protect domestic water supplies from contamination. Mortgagees should contact the local health departments and/or state and local agencies with regard to any jurisdictional requirements for the installation and/or use of the RPZ device on all wet heat systems. Mortgagees should obtain two independent competitive bids. Winterization In jurisdictions where winterization is required, properties are to be winterized between October 1st and March 31st. Properties should only be winterized once. However, a property should be re-winterized if the initial winterization is violated (no longer effective) and the Mortgagee obtains prior approval from the M&M Contractor. Unless otherwise specified by local variation, the winterization process must include cleaning toilets and draining of all plumbing and heating systems in a manner sufficient to prevent freeze and/or other damage. Use of air pressure to clear the system, or in some cases, adding antifreeze to the system is both acceptable, provided that the effect prevents freeze-ups. All winterization should be performed in accordance with state and local codes, ordinances and regulations. Before and after photographs are required along with any other supporting documentation to support a claim for re-imbursement. Dry Heat Systems The hot water heater and all domestic water supply and distribution piping must be drained in a manner sufficient to prevent freeze and/or other damage. All faucets and valves should REMAIN OPEN during the process, and then closed after draining is completed. Adequate amounts of antifreeze are to be placed in all fixture traps, including toilet tanks and bowls. Wet Heat, Radiant, Hydronic or Hot Water Baseboard Systems The winterization requirements outlined above apply. In addition, the house boiler system must be drained in a manner sufficient to prevent freeze and/or other damage. All radiator vents are to be opened in the process. Bleeder pins should not be removed from the radiators. Any radiant heat piping should be drained and blown dry with the use of an air compressor and an adequate amount of antifreeze is to be put in the radiant piping. Steam Heat Systems A steam heat system will have radiators with valves at the bottom of the radiator; a careful determination as to whether the system is hot water or steam is important to ensure proper action is taken. The Mortgagee should determine if the system is operable and if there are any leaks. If any problems with the steam heat system exist, this information should be reported to the M&M Contractor. Additionally, the Mortgagee must drain the property’s boiler system in a manner sufficient to prevent freeze and/or other damage. All radiator vents are to be opened in the process and bleeder pins should not be removed from the radiators, before shutting down the heating system. Pressurize the system with an air compressor to 35 pounds and inspect for leakage. The expectation for a properly prepared system is that it will hold air pressure with no leakage for a minimum of one-half hour
Posted on: Sat, 01 Feb 2014 07:09:53 +0000

Trending Topics



e="min-height:30px;">
Want to Win one weapon Skins On CS: Go? Especially a PP-Bizon
So we have been almost 3 weeks with out power. I worry all the
We need to pray for our Judicial system because it needs all the
Hi there. My name is Jared Meyers. I have been marketing online

Recently Viewed Topics




© 2015