What is the Legally Allowed Construction for a Plot Size as per - TopicsExpress



          

What is the Legally Allowed Construction for a Plot Size as per Rules? Planning to purchase a plot and construct a house on your own in GHMC limits? You need to consider the below mentioned setbacks and height stipulations to comply with the Andhra Pradesh Building Rules issued by the department of municipal administration and urban development. Sl. No. Plot Size (In Sq. Yards) Parking Provision Height (in Feet ) Permissible Up to Minimum Front Setback to be Left (in feet) Minimum Setback On Remaining Sides (in Feet) Abutting Road width Up to 39’4″ >39’4″ to 59′ >59′ to 78’6″ >78’6″ to 98’3″ > 98’3″ Sl. No. Plot Size (In Sq. Yards) Parking Provision Height (in Feet ) Permissible Up to Minimum Front Setback to be Left (in feet) Minimum Setback On Remaining Sides (in Feet) Abutting Road width Up to 39’4″ >39’4″ to 59′ >59′ to 78’6″ >78’6″ to 98’3″ > 98’3″ 1 Less than 60 sq yd 22’10″ 4’9″ 4’9″ 9’8″ 9’8″ 9’8″ 2 60 – 120 sq yd 22’10″ 4’9″ 4’9″ 9’8″ 9’8″ 9’8″ - 32’8″ 4’9″ 4’9″ 9’8″ 9’8″ 9’8″ 1’6″ 3 120 – 239 sq yd - 32’8″ 4’9″ 4’9″ 9’8″ 9’8″ 9’8″ 3’3″ 4 239 – 359 sq yd Stilt Floor 22’10″ 6’6″ 9’8″ 9’8″ 13’1″ 16’4″ 3’3″ 32’8″ 6’6″ 9’8″ 9’8″ 16’4″ 19’7″ 4’9″ 5 359 – 478 sq yd Stilt Floor 22’10″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 4’9″ 39’4″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 6’6″ 6 478 – 598 sq yd Stilt Floor 22’10″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 6’6″ 39’4″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 8’2″ 7 598 – 897 sq yd Stilt Floor 22’10″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 8’2″ 39’4″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 9’8″ 49’2″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 11’5″ 8 897 – 1196 sq yd Stilt + One Cellar Floor 22’10″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 9’8″ 39’4″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 11’5″ 49’2″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 13’1″ 9 1196 -1794 sq yd Stilt + 2 cellar Floors 22’10″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 11’5″ 39’4″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 13’1″ 49’2″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 16’4″ 59′ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 19’7″ 10 1794 – 2990 sq yd Stilt + 2 cellar Floors 22’10″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 13’1″ 49’2″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 16’4″ 59′ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 19’7″ 11 Above 2990 sq yd Stilt + 2 or more Cellar Floors 22’10″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 16’4″ 49’2″ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 19’7″ 59′ 9’8″ 13’1″ 16’4″ 19’7″ 24’6″ 22’10″ Stilt floor for parking is not included in the permissible height. Height of stilt floor should not be less than 8’2″. The parking floor should not be less than 14’7″ in height if mechanical system and lift is provided. Buildings of height above 49’5″ and below feet (those in Sl.Nos. 9, 10 and 11) will be permitted only if such plots have a minimum of 39′ wide roads only.
Posted on: Mon, 05 May 2014 04:55:31 +0000

Trending Topics



Recently Viewed Topics




© 2015